Determination of diethylene glycol in cosmetics with gas chromatography
-
摘要:
目的 针对《化妆品技术规范》(2015年版)中测定化妆品中二甘醇方法的局限性,建立气相色谱法检测不同基质的化妆品(水、乳、霜、凝胶、膏)中二甘醇含量的方法。 方法 水状样品用甲醇超声提取后直接过滤上样,乳、霜、凝胶等样品用甲醇超声提取,离心后过滤上样,膏状样品先用无水硫酸钠研磨,甲醇超声提取,离心过滤后上样检测,采用气相色谱 – 氢火焰离子化检测器进行测定,基质匹配标准溶液外标法定量。 结果 二甘醇在1~1 000 μg/mL浓度范围内线性关系良好(r = 0.9997)。选取高中低3个浓度添加二甘醇标准品,乳、霜、凝胶的回收率为94.4 %~95.4 %,膏的回收率为85.1 %~96.9 %,化妆水的回收率为89.5 %~98.8 %,且相对标准偏差(RSD)均≤4.86 %。方法检出限为0.24 μg/mL,定量限为1 μg/mL。 结论 该方法操作简单可行,测量成本低,线性范围宽,实用价值高,适用于不同基质的化妆品中二甘醇含量的检测。 Abstract:Objective To develop a method for the determination of diethylene glycol in various cosmetics (emollient water, lotion, cream, gel and paste) with gas chromatography to solve limitations of detection methods used in current practice. Methods The emollient water samples were extracted with methanol by ultrasonic and detected after filtration; the lotion, cream and gel samples were extracted with methanol with ultrasonic and then centrifuged and filtered; the paste samples were grinded with anhydrous sodium sulfate first, then extracted using ultrasonic with methanol, and finally centrifuged and filtered for detection. The diethylene glycol in the samples was determined with gas chromatography-flame ionization detector (GC-FID) and quantified with matrix-matched external standard method. Results The calibration curve presented a good linearity in the range of 1 – 1000 μg/mL (r = 0.999 7). Three-level spiked recoveries were carried out using blank cosmetic extractions as substrate; the recoveries ranged from 94.4% to 95.4% for lotion, cream or gel, 85.1% to 96.9% for the paste, and 89.5% to 98.8% for emollient water; while the relative standard deviations (RSDs) were all below 4.86%. The limit of determination was 0.24 μg/mL and the limit of quantitation was 1 μg/mL. Conclusion The method is simple and easy to operate with less cost, wide linear rang, low detection linearity, and high practical value and it is suitable for the detection of diethylene glycol in different cosmetic matrixes. -
Key words:
- diethylene glycol /
- cosmetics /
- gas chromatography
-
表 1 二甘醇的线性方程及灵敏度
工作曲线 线性范围(μg/mL) 校准曲线 r LOD(μg/mL) LOQ(μg/mL) 1 1~100 A = – 0.0117 + 0.692C 0.9997 0.24 1 2 50~1 000 A = 8.0083 + 0.6327C 0.9997 表 2 样品加标回收率和精密度
样品 二甘醇(μg/mL) 平均回收率(%) RSDs(%) 实际加入量 平均检测量 日间(n = 6) 日内(n = 5) 乳、霜、凝胶 10 9.44 94.4 3.77 3.82 100 94.53 94.5 3.26 4.08 800 763.19 95.4 2.17 3.12 膏 10 8.51 85.1 3.41 3.04 100 86.23 86.2 2.92 3.73 800 775.49 96.9 1.22 1.08 化妆水 10 8.95 89.5 4.10 4.63 100 90.48 90.5 2.15 4.86 800 790.19 98.8 3.80 2.58 -
[1] Williams RH, Shah SM, Maggiore JA, et al. Simultaneous detection and quantitation of diethylene glycol, ethylene glycol, and the toxic alcohols in serum using capillary column gas chromatography[J]. Journal of Analytical Toxicology, 2000, 24(7): 621 – 626. [2] 王冉, 方舒正, 汪俊涵, 等. 化妆品中二甘醇的风险评估[J]. 中国工业医学杂志, 2011, 24(4): 279 – 281. [3] Maurer HH, Peters FT, Paul LD, et al. Validated gas chromatographic-mass spectrometric assay for determination of the antifreezes ethylene glycol and diethylene glycol in human plasma after microwave-assisted pivalylation[J]. Journal of Chroma-tography B: Biomedical Sciences and Applications, 2001, 754(2): 401 – 409. [4] 余雯静, 郑晨, 赵玉兰, 等. 气相色谱/质谱联用检测唇用产品中二甘醇的残留[J]. 香料香精化妆品, 2011, 2: 35 – 37. [5] 余雯静, 郑晨, 赵玉兰. 气质联用法检测日用化学品中二甘醇[J]. 环境科技, 2010, 23(2): 71 – 73. [6] Self RL. Direct analysis in real time-mass spectrometry (DART-MS) for rapid qualitative screening of toxic glycols in glycerin-containing products[J]. Journal of Pharmaceutical and Biomedical Analysis, 2013, 80: 155 – 158. [7] Rahim AA, Saad B, Osman H, et al. Simultaneous determination of diethylene glycol, diethylene glycol monoethyl ether, coumarin and caffeine in food items by gas chromatography[J]. Food Chemistry, 2011, 126(3): 1412 – 1416. [8] Bahaa NEA, Dhifaf MSA. Detection of diethylene glycol in toothpaste[J]. Al-Mustansiriyah Journal for Pharmaceutical Sciences, 2011, 9(1): 43 – 51. [9] Barry S, Wolff JC. Investigation into the quantitative analysis of diethylene glycol in toothpaste by direct analysis in real time mass spectrometry[J]. Rapid Communications in Mass Spectrometry:RCM, 2016, 30(15): 1829 – 1834. [10] Wu JG, Yuan JB, Liu Q, et al. New derivatizing reagent for analysis of diethylene glycol by HPLC with fluorescence detection[J]. Journal of Separation Science, 2008, 31(22): 3857 – 3863. [11] Hernández F, Ibáñez M, Sancho JV. Fast determination of toxic diethylene glycol in toothpaste by ultra-performance liquid chromatography-time of flight mass spectrometry[J]. Analytical and Bioanalytical Chemistry, 2008, 391(3): 1021 – 1027. [12] Baffi P, Elneser S, Baffi M, et al. Quantitative determination of diethylene glycol contamination in pharmaceutical products[J]. Journal of AOAC International, 2000, 83(4): 793 – 801. [13] 范茂林, 杨旭东, 艾雨, 等. 尿液中尼古丁和可替宁QuEChERS预处理气相色谱测定法建立[J]. 中国公共卫生, 2017, 2: 333 – 337. [14] Zhu K, Gu B, Kerry M, et al. Elimination of N, O-bis (trimethylsilyl) trifluoroacetamide interference by base treatment in derivatization gas chromatography mass spectrometry determinationof parts per billion of alcohols in a food additive[J]. Journal of Chromatography A, 2017, 1490: 74 – 79. [15] Wurita A, Suzuki O, Hasegawa K, et al. Sensitive determination of ethylene glycol, propylene glycol and diethylene glycol in human whole blood by isotope dilution gas chromatography-mass spectrometry, and the presence of appreciable amounts of the glycols in blood of healthy subjects[J]. Forensic Toxicology, 2013, 31(2): 272 – 280.