Objective To explore the sterile effect and possible mechanism of the water treatment equipment of compound electromagnetic field(equipment for short).
Methods Sterilization Test: The simulated water prepared with 8 099 of Escherichia coli(E.coli)were treated by the equipment for 60 s.During the treatment, the water samples were taken in 0, 15, 30, 45 and 60s and immediately incubated at 37℃ and 44.5℃ to deter mine the densities of E.coli.Continual Sterilization Test: Three kinds of water were made: (1)Tap water disposed with autoclave.(2)Dechloridizedtap water treated by the sterile state of the equipment for 3 min.(3)Dechloridizedtap water treated by the sterile state of the equipment for 3 min and colloidal pr ecipitation state of the equipment for 20 min.8 099 of E.coli Were added in these three kinds of water and stayed there for 3 h.During the treatment, the water samples were taken in 0, 0.5, 1, 2 and 3 h and incubated at 37℃ and 44.5℃ to determine the densities of E.coli.
Results (1) The sterile ratio of the simulated water sample was 100% in 30 s by the equipment.(2)The sterile ratio of the water sample readded bacteria was 100% in 60 min.
Conclusion The equipmenthas rapid and effective sterile effect and some continual sterile effect.