Objective To develop sandwich immune-PCR system for monitoring antigen.
Methods Avidin was used to bridge the biotinylated antibodies and biotinylated DNA, and to detect antigen by immuno-PCR.
Results As little as 0.1ng/L of SEB could be detected by the sandwich immuno-PCR, which was 103 times more sensitive than ELISA parallel control.
Conclusion The universal immuno-PCR system can be used to detect ultra-micro antigen.